The TRCVICTLR controls instruction trace filtering
SEL0 | Selects the resource number, based on the value of TYPE0: When TYPE1 is 0, selects a single selected resource from 0-15 defined by SEL0[2:0]. When TYPE1 is 1, selects a Boolean combined resource pair from 0-7 defined by SEL0[2:0] |
TYPE0 | Selects the resource type for event 0 |
SSSTATUS | Indicates the current status of the start/stop logic |
TRCRESET | Selects whether a reset exception must always be traced |
TRCERR | Selects whether a system error exception must always be traced |
EXLEVEL_S0 | In Secure state, each bit controls whether instruction tracing is enabled for the corresponding exception level |
EXLEVEL_S3 | In Secure state, each bit controls whether instruction tracing is enabled for the corresponding exception level |